RX 400p
4-59 98-05044
R1
Table 4-1 Beacon Health Status Values
Health Code Indication
0 - 5 Reference Station Transmission Broadcast – Monitored
6 Reference Station Transmission Broadcast – Unmonitored
7 Reference Station Not Working
4.12.2 Beacon Configure Menu
This menu provides access to the various methods to tune the internal SBX beacon
sensor inside the RX 400p. This submenu is detailed in Figure 4-12.
Diff@Beacon? $
Tune@Auto Auto?^
Auto?Tune@
TuneBeaconName@
Table Version@
Back@
Top?Menu@
Pressing the
and keys allows you to scroll through the available options.
Pressing the
button with any item in focus will take the menu system to that
submenu. Pressing the
button with the Back@ or Top Menu@ item in focus will
take the menu system to the previous menu or the Main menu, respectively.
Diff@Beacon
Using the button, this menu item allows you to
choose the source of differential corrections.
Correction source options include the WAAS
demodulator, internal OmniSTAR receiver, the
internal beacon receiver, use of external corrections,
or autonomous operation.
Vue de la page 100